CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2023-5391 | 1 Schneider-electric | 3 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports, Ecostruxure Power Scada Operation With Advanced Reports | 2025-02-27 | 9.8 Critical |
A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker to execute arbitrary code on the targeted system by sending a specifically crafted packet to the application. | ||||
CVE-2024-10498 | 1 Schneider-electric | 1 Powerlogic Hdpm6000 | 2025-02-12 | 6.5 Medium |
CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could allow an unauthorized attacker to modify configuration values outside of the normal range when the attacker sends specific Modbus write packets to the device which could result in invalid data or loss of web interface functionality. | ||||
CVE-2023-25551 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2025-02-12 | 6.1 Medium |
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE file upload endpoint when tampering with parameters over HTTP. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) | ||||
CVE-2023-25550 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2025-02-12 | 7.2 High |
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows remote code execution via the “hostname” parameter when maliciously crafted hostname syntax is entered. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) | ||||
CVE-2023-25554 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2025-02-12 | 7.8 High |
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that allows a local privilege escalation on the appliance when a maliciously crafted Operating System command is entered on the device. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) | ||||
CVE-2023-25547 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2025-02-12 | 8.8 High |
A CWE-863: Incorrect Authorization vulnerability exists that could allow remote code execution on upload and install packages when a hacker is using a low privileged user account. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) | ||||
CVE-2023-25555 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2025-02-05 | 5.6 Medium |
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow a user that knows the credentials to execute unprivileged shell commands on the appliance over SSH. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) | ||||
CVE-2023-25553 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2025-02-05 | 6.1 Medium |
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE endpoint through the logging capabilities of the webserver. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) | ||||
CVE-2023-28003 | 1 Schneider-electric | 1 Ecostruxure Power Monitoring Expert | 2025-02-05 | 6.7 Medium |
A CWE-613: Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain unauthorized access over a hijacked session in PME after the legitimate user has signed out of their account. | ||||
CVE-2023-29411 | 2 Microsoft, Schneider-electric | 7 Windows 10, Windows 11, Windows Server 2016 and 4 more | 2025-02-05 | 9.8 Critical |
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior authentication on the Java RMI interface. | ||||
CVE-2023-25556 | 1 Schneider-electric | 14 Merten Instabus Tastermodul 1fach System M, Merten Instabus Tastermodul 1fach System M Firmware, Merten Instabus Tastermodul 2fach System M and 11 more | 2025-02-05 | 8.3 High |
A CWE-287: Improper Authentication vulnerability exists that could allow a device to be compromised when a key of less than seven digits is entered and the attacker has access to the KNX installation. | ||||
CVE-2023-1548 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2025-02-05 | 5.5 Medium |
A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to perform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products: EcoStruxure Control Expert (V15.1 and above) | ||||
CVE-2023-27976 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2025-02-05 | 8.8 High |
A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause remote code execution when a valid user visits a malicious link provided through the web endpoints. Affected Products: EcoStruxure Control Expert (V15.1 and above) | ||||
CVE-2023-29412 | 2 Microsoft, Schneider-electric | 7 Windows 10, Windows 11, Windows Server 2016 and 4 more | 2025-02-05 | 9.8 Critical |
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when manipulating internal methods through Java RMI interface. | ||||
CVE-2023-29413 | 2 Microsoft, Schneider-electric | 7 Windows 10, Windows 11, Windows Server 2016 and 4 more | 2025-02-05 | 7.5 High |
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor service. | ||||
CVE-2023-29410 | 1 Schneider-electric | 6 Conext Gateway, Conext Gateway Firmware, Insightfacility and 3 more | 2025-02-05 | 7.2 High |
A CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated attacker to gain the same privilege as the application on the server when a malicious payload is provided over HTTP for the server to execute. | ||||
CVE-2022-43377 | 1 Schneider-electric | 10 Netbotz 355, Netbotz 355 Firmware, Netbotz 450 and 7 more | 2025-02-05 | 7.5 High |
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause account takeover when a brute force attack is performed on the account. Affected Products: NetBotz 4 - 355/450/455/550/570 (V4.7.0 and prior) | ||||
CVE-2022-32513 | 1 Schneider-electric | 12 5500ac2, 5500ac2 Firmware, 5500nac and 9 more | 2025-02-05 | 9.8 Critical |
A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0) | ||||
CVE-2022-32514 | 1 Schneider-electric | 12 5500ac2, 5500ac2 Firmware, 5500nac and 9 more | 2025-02-05 | 9.8 Critical |
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0) | ||||
CVE-2022-32522 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted mathematically reduced data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) |