Filtered by vendor Tenda
Subscriptions
Filtered by product O3
Subscriptions
Total
19 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2025-7421 | 1 Tenda | 2 O3, O3 Firmware | 2025-07-16 | 8.8 High |
A vulnerability was found in Tenda O3V2 1.0.0.12(3880). It has been rated as critical. This issue affects the function fromMacFilterModify of the file /goform/operateMacFilter of the component httpd. The manipulation of the argument mac leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-7422 | 1 Tenda | 2 O3, O3 Firmware | 2025-07-16 | 8.8 High |
A vulnerability classified as critical has been found in Tenda O3V2 1.0.0.12(3880). Affected is the function setAutoReboot of the file /goform/setNetworkService of the component httpd. The manipulation of the argument week leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-7423 | 1 Tenda | 2 O3, O3 Firmware | 2025-07-16 | 8.8 High |
A vulnerability classified as critical was found in Tenda O3V2 1.0.0.12(3880). Affected by this vulnerability is the function formWifiMacFilterSet of the file /goform/setWrlFilterList of the component httpd. The manipulation of the argument macList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-7417 | 1 Tenda | 2 O3, O3 Firmware | 2025-07-16 | 8.8 High |
A vulnerability has been found in Tenda O3V2 1.0.0.12(3880) and classified as critical. Affected by this vulnerability is the function fromNetToolGet of the file /goform/setPingInfo of the component httpd. The manipulation of the argument ip leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-7418 | 1 Tenda | 2 O3, O3 Firmware | 2025-07-16 | 8.8 High |
A vulnerability was found in Tenda O3V2 1.0.0.12(3880) and classified as critical. Affected by this issue is the function fromPingResultGet of the file /goform/setPing of the component httpd. The manipulation of the argument destIP leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-7419 | 1 Tenda | 2 O3, O3 Firmware | 2025-07-16 | 8.8 High |
A vulnerability was found in Tenda O3V2 1.0.0.12(3880). It has been classified as critical. This affects the function fromSpeedTestSet of the file /goform/setRateTest of the component httpd. The manipulation of the argument destIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-7420 | 1 Tenda | 2 O3, O3 Firmware | 2025-07-16 | 8.8 High |
A vulnerability was found in Tenda O3V2 1.0.0.12(3880). It has been declared as critical. This vulnerability affects the function formWifiBasicSet of the file /goform/setWrlBasicInfo of the component httpd. The manipulation of the argument extChannel leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-7414 | 1 Tenda | 2 O3, O3 Firmware | 2025-07-16 | 6.3 Medium |
A vulnerability classified as critical was found in Tenda O3V2 1.0.0.12(3880). This vulnerability affects the function fromNetToolGet of the file /goform/setPingInfo of the component httpd. The manipulation of the argument domain leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-7415 | 1 Tenda | 2 O3, O3 Firmware | 2025-07-16 | 6.3 Medium |
A vulnerability, which was classified as critical, has been found in Tenda O3V2 1.0.0.12(3880). This issue affects the function fromTraceroutGet of the file /goform/getTraceroute of the component httpd. The manipulation of the argument dest leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-7416 | 1 Tenda | 2 O3, O3 Firmware | 2025-07-16 | 8.8 High |
A vulnerability, which was classified as critical, was found in Tenda O3V2 1.0.0.12(3880). Affected is the function fromSysToolTime of the file /goform/setSysTimeInfo of the component httpd. The manipulation of the argument Time leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2024-34338 | 1 Tenda | 3 O3, O3 Firmware, O3v2 | 2025-06-30 | 7.2 High |
Tenda O3V2 with firmware versions V1.0.0.10 and V1.0.0.12 was discovered to contain a Blind Command Injection via dest parameter in /goform/getTraceroute. This vulnerability allows attackers to execute arbitrary commands with root privileges. Authentication is required to exploit this vulnerability. | ||||
CVE-2024-51409 | 1 Tenda | 2 O3, O3 Firmware | 2025-04-11 | 6.5 Medium |
Buffer Overflow vulnerability in Tenda O3 v.1.0.0.5 allows a remote attacker to cause a denial of service via a network packet in a fixed format to a router running the corresponding version of the firmware. | ||||
CVE-2024-36604 | 1 Tenda | 2 O3, O3 Firmware | 2025-02-13 | 9.8 Critical |
Tenda O3V2 v1.0.0.12(3880) was discovered to contain a Blind Command Injection via stpEn parameter in the SetStp function. This vulnerability allows attackers to execute arbitrary commands with root privileges. | ||||
CVE-2024-7152 | 1 Tenda | 2 O3, O3 Firmware | 2024-11-21 | 8.8 High |
A vulnerability was found in Tenda O3 1.0.0.10(2478). It has been rated as critical. This issue affects the function fromSafeSetMacFilter of the file /goform/setMacFilterList. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272555. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-7151 | 1 Tenda | 2 O3, O3 Firmware | 2024-11-21 | 8.8 High |
A vulnerability was found in Tenda O3 1.0.0.10(2478). It has been declared as critical. This vulnerability affects the function fromMacFilterSet of the file /goform/setMacFilter. The manipulation of the argument remark leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-272554 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-6965 | 1 Tenda | 2 O3, O3 Firmware1.0.0.10\(2478\) | 2024-11-21 | 8.8 High |
A vulnerability has been found in Tenda O3 1.0.0.10 and classified as critical. Affected by this vulnerability is the function fromVirtualSet. The manipulation of the argument ip/localPort/publicPort/app leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272119. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-6964 | 1 Tenda | 2 O3, O3 Firmware1.0.0.10\(2478\) | 2024-11-21 | 8.8 High |
A vulnerability, which was classified as critical, was found in Tenda O3 1.0.0.10. Affected is the function fromDhcpSetSer. The manipulation of the argument dhcpEn/startIP/endIP/preDNS/altDNS/mask/gateway leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-272118 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-6963 | 1 Tenda | 3 O3, O3 Firmware1.0.0.10\(2478\), O3v2 Firmware | 2024-11-21 | 8.8 High |
A vulnerability, which was classified as critical, has been found in Tenda O3 1.0.0.10. This issue affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-272117 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-6962 | 1 Tenda | 3 O3, O3 Firmware1.0.0.10\(2478\), O3v2 | 2024-11-21 | 8.8 High |
A vulnerability classified as critical was found in Tenda O3 1.0.0.10. This vulnerability affects the function formQosSet. The manipulation of the argument remark/ipRange/upSpeed/downSpeed/enable leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-272116. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |