Filtered by vendor Advantech Subscriptions
Total 317 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2022-3323 1 Advantech 1 Iview 2024-11-21 7.5 High
An SQL injection vulnerability in Advantech iView 5.7.04.6469. The specific flaw exists within the ConfigurationServlet endpoint, which listens on TCP port 8080 by default. An unauthenticated remote attacker can craft a special column_value parameter in the setConfiguration action to bypass checks in com.imc.iview.utils.CUtils.checkSQLInjection() to perform SQL injection. For example, the attacker can exploit the vulnerability to retrieve the iView admin password.
CVE-2021-42706 1 Advantech 1 Webaccess Hmi Designer 2024-11-21 7.8 High
This vulnerability could allow an attacker to disclose information and execute arbitrary code on affected installations of WebAccess/MHI Designer
CVE-2021-42703 1 Advantech 1 Webaccess Hmi Designer 2024-11-21 5.4 Medium
This vulnerability could allow an attacker to send malicious Javascript code resulting in hijacking of the user’s cookie/session tokens, redirecting the user to a malicious webpage, and performing unintended browser action.
CVE-2021-38431 1 Advantech 1 Webaccess Scada 2024-11-21 4.3 Medium
An authenticated user using Advantech WebAccess SCADA in versions 9.0.3 and prior can use API functions to disclose project names and paths from other users.
CVE-2021-38408 1 Advantech 1 Webaccess 2024-11-21 9.8 Critical
A stack-based buffer overflow vulnerability in Advantech WebAccess Versions 9.02 and prior caused by a lack of proper validation of the length of user-supplied data may allow remote code execution.
CVE-2021-38389 1 Advantech 1 Webaccess 2024-11-21 9.8 Critical
Advantech WebAccess versions 9.02 and prior are vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute code.
CVE-2021-34540 1 Advantech 1 Webaccess 2024-11-21 6.1 Medium
Advantech WebAccess 8.4.2 and 8.4.4 allows XSS via the username column of the bwRoot.asp page of WADashboard.
CVE-2021-33023 1 Advantech 1 Webaccess 2024-11-21 9.8 Critical
Advantech WebAccess versions 9.02 and prior are vulnerable to a heap-based buffer overflow, which may allow an attacker to remotely execute code.
CVE-2021-33004 1 Advantech 1 Webaccess\/hmi Designer 2024-11-21 7.8 High
The affected product is vulnerable to memory corruption condition due to lack of proper validation of user supplied files, which may allow an attacker to execute arbitrary code. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95 and prior).
CVE-2021-33002 1 Advantech 1 Webaccess\/hmi Designer 2024-11-21 7.8 High
Opening a maliciously crafted project file may cause an out-of-bounds write, which may allow an attacker to execute arbitrary code. User interaction is require on the WebAccess HMI Designer (versions 2.1.9.95 and prior).
CVE-2021-33000 1 Advantech 1 Webaccess\/hmi Designer 2024-11-21 7.8 High
Parsing a maliciously crafted project file may cause a heap-based buffer overflow, which may allow an attacker to perform arbitrary code execution. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95 and prior).
CVE-2021-32956 1 Advantech 1 Webaccess\/scada 2024-11-21 6.1 Medium
Advantech WebAccess/SCADA Versions 9.0.1 and prior is vulnerable to redirection, which may allow an attacker to send a maliciously crafted URL that could result in redirecting a user to a malicious webpage.
CVE-2021-32954 1 Advantech 1 Webaccess\/scada 2024-11-21 6.5 Medium
Advantech WebAccess/SCADA Versions 9.0.1 and prior is vulnerable to a directory traversal, which may allow an attacker to remotely read arbitrary files on the file system.
CVE-2021-32951 1 Advantech 1 Webaccess\/nms 2024-11-21 5.3 Medium
WebAccess/NMS (Versions prior to v3.0.3_Build6299) has an improper authentication vulnerability, which may allow unauthorized users to view resources monitored and controlled by the WebAccess/NMS, as well as IP addresses and names of all the devices managed via WebAccess/NMS.
CVE-2021-32943 1 Advantech 1 Webaccess\/scada 2024-11-21 9.8 Critical
The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1).
CVE-2021-32932 1 Advantech 1 Iview 2024-11-21 7.5 High
The affected product is vulnerable to a SQL injection, which may allow an unauthorized attacker to disclose information on the iView (versions prior to v5.7.03.6182).
CVE-2021-32930 1 Advantech 1 Iview 2024-11-21 9.8 Critical
The affected product’s configuration is vulnerable due to missing authentication, which may allow an attacker to change configurations and execute arbitrary code on the iView (versions prior to v5.7.03.6182).
CVE-2021-27437 1 Advantech 1 Wise-paas\/rmm 2024-11-21 9.1 Critical
The affected product allows attackers to obtain sensitive information from the WISE-PaaS dashboard. The system contains a hard-coded administrator username and password that can be used to query Grafana APIs. Authentication is not required for exploitation on the WISE-PaaS/RMM (versions prior to 9.0.1).
CVE-2021-27436 1 Advantech 1 Webaccess\/scada 2024-11-21 6.1 Medium
WebAccess/SCADA Versions 9.0 and prior is vulnerable to cross-site scripting, which may allow an attacker to send malicious JavaScript code to an unsuspecting user, which could result in hijacking of the user’s cookie/session tokens, redirecting the user to a malicious webpage and performing unintended browser actions.
CVE-2021-22676 1 Advantech 1 Webaccess\/scada 2024-11-21 6.1 Medium
UserExcelOut.asp within WebAccess/SCADA is vulnerable to cross-site scripting (XSS), which could allow an attacker to send malicious JavaScript code. This could result in hijacking of cookie/session tokens, redirection to a malicious webpage, and unintended browser action on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1).