Total
1492 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2018-4838 | 1 Siemens | 10 En100 Ethernet Module Dnp3, En100 Ethernet Module Dnp3 Firmware, En100 Ethernet Module Iec 104 and 7 more | 2024-11-21 | N/A |
A vulnerability has been identified in EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module DNP3 variant (All versions < V1.04), EN100 Ethernet module PROFINET IO variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions < V1.22). The web interface (TCP/80) of affected devices allows an unauthenticated user to upgrade or downgrade the firmware of the device, including to older versions with known vulnerabilities. | ||||
CVE-2018-4834 | 1 Siemens | 10 Pxc001-e.d, Pxc001-e.d Firmware, Pxc00\/50\/100\/200-e.d and 7 more | 2024-11-21 | 9.8 Critical |
A vulnerability has been identified in Desigo PXC00-E.D V4.10 (All versions < V4.10.111), Desigo PXC00-E.D V5.00 (All versions < V5.0.171), Desigo PXC00-E.D V5.10 (All versions < V5.10.69), Desigo PXC00-E.D V6.00 (All versions < V6.0.204), Desigo PXC00/64/128-U V4.10 (All versions < V4.10.111 only with web module), Desigo PXC00/64/128-U V5.00 (All versions < V5.0.171 only with web module), Desigo PXC00/64/128-U V5.10 (All versions < V5.10.69 only with web module), Desigo PXC00/64/128-U V6.00 (All versions < V6.0.204 only with web module), Desigo PXC001-E.D V4.10 (All versions < V4.10.111), Desigo PXC001-E.D V5.00 (All versions < V5.0.171), Desigo PXC001-E.D V5.10 (All versions < V5.10.69), Desigo PXC001-E.D V6.00 (All versions < V6.0.204), Desigo PXC100-E.D V4.10 (All versions < V4.10.111), Desigo PXC100-E.D V5.00 (All versions < V5.0.171), Desigo PXC100-E.D V5.10 (All versions < V5.10.69), Desigo PXC100-E.D V6.00 (All versions < V6.0.204), Desigo PXC12-E.D V4.10 (All versions < V4.10.111), Desigo PXC12-E.D V5.00 (All versions < V5.0.171), Desigo PXC12-E.D V5.10 (All versions < V5.10.69), Desigo PXC12-E.D V6.00 (All versions < V6.0.204), Desigo PXC200-E.D V4.10 (All versions < V4.10.111), Desigo PXC200-E.D V5.00 (All versions < V5.0.171), Desigo PXC200-E.D V5.10 (All versions < V5.10.69), Desigo PXC200-E.D V6.00 (All versions < V6.0.204), Desigo PXC22-E.D V4.10 (All versions < V4.10.111), Desigo PXC22-E.D V5.00 (All versions < V5.0.171), Desigo PXC22-E.D V5.10 (All versions < V5.10.69), Desigo PXC22-E.D V6.00 (All versions < V6.0.204), Desigo PXC22.1-E.D V4.10 (All versions < V4.10.111), Desigo PXC22.1-E.D V5.00 (All versions < V5.0.171), Desigo PXC22.1-E.D V5.10 (All versions < V5.10.69), Desigo PXC22.1-E.D V6.00 (All versions < V6.0.204), Desigo PXC36.1-E.D V4.10 (All versions < V4.10.111), Desigo PXC36.1-E.D V5.00 (All versions < V5.0.171), Desigo PXC36.1-E.D V5.10 (All versions < V5.10.69), Desigo PXC36.1-E.D V6.00 (All versions < V6.0.204), Desigo PXC50-E.D V4.10 (All versions < V4.10.111), Desigo PXC50-E.D V5.00 (All versions < V5.0.171), Desigo PXC50-E.D V5.10 (All versions < V5.10.69), Desigo PXC50-E.D V6.00 (All versions < V6.0.204), Desigo PXM20-E V4.10 (All versions < V4.10.111), Desigo PXM20-E V5.00 (All versions < V5.0.171), Desigo PXM20-E V5.10 (All versions < V5.10.69), Desigo PXM20-E V6.00 (All versions < V6.0.204). A remote attacker with network access to the device could potentially upload a new firmware image to the devices without prior authentication. | ||||
CVE-2018-2368 | 1 Sap | 1 Netweaver System Landscape Directory | 2024-11-21 | N/A |
SAP NetWeaver System Landscape Directory, LM-CORE 7.10, 7.20, 7.30, 7.31, 7.40, does not perform any authentication checks for functionalities that require user identity. | ||||
CVE-2018-2360 | 1 Sap | 1 Sap Kernel | 2024-11-21 | N/A |
SAP Startup Service, SAP KERNEL 7.45, 7.49, and 7.52, is missing an authentication check for functionalities that require user identity and cause consumption of file system storage. | ||||
CVE-2018-21132 | 1 Netgear | 4 Wac505, Wac505 Firmware, Wac510 and 1 more | 2024-11-21 | 9.8 Critical |
Certain NETGEAR devices are affected by authentication bypass. This affects WAC505 before 5.0.0.17 and WAC510 before 5.0.0.17. | ||||
CVE-2018-21041 | 1 Google | 1 Android | 2024-11-21 | 7.5 High |
An issue was discovered on Samsung mobile devices with O(8.x) software. Access to Gallery in the Secure Folder can occur without authentication. The Samsung ID is SVE-2018-13057 (December 2018). | ||||
CVE-2018-20507 | 1 Gitlab | 1 Gitlab | 2024-11-21 | 5.3 Medium |
An issue was discovered in GitLab Enterprise Edition 11.2.x through 11.4.x before 11.4.13, 11.5.x before 11.5.6, and 11.6.x before 11.6.1. It has Incorrect Access Control. | ||||
CVE-2018-20220 | 1 Teracue | 6 Enc-400 Hdmi, Enc-400 Hdmi2, Enc-400 Hdmi2 Firmware and 3 more | 2024-11-21 | N/A |
An issue was discovered on Teracue ENC-400 devices with firmware 2.56 and below. While the web interface requires authentication before it can be interacted with, a large portion of the HTTP endpoints are missing authentication. An attacker is able to view these pages before being authenticated, and some of these pages may disclose sensitive information. | ||||
CVE-2018-1757 | 1 Ibm | 1 Security Identity Governance And Intelligence | 2024-11-21 | N/A |
IBM Security Identity Governance and Intelligence 5.2.3.2 and 5.2.4 could allow an attacker to obtain sensitive information due to missing authentication in IGI for the survey application. IBM X-Force ID: 148601. | ||||
CVE-2018-1745 | 1 Ibm | 1 Security Key Lifecycle Manager | 2024-11-21 | N/A |
IBM Security Key Lifecycle Manager 2.7 and 3.0 could allow an unauthenticated user to restart the SKLM server due to missing authentication. IBM X-Force ID: 148424. | ||||
CVE-2018-1501 | 1 Ibm | 1 Security Guardium | 2024-11-21 | 7.5 High |
IBM Security Guardium 10.5, 10.6, and 11.0 could allow an unauthorized user to obtain sensitive information due to missing security controls. IBM X-Force ID: 141226. | ||||
CVE-2018-1164 | 1 Zyxel | 2 P-870h-51, P-870h-51 Firmware | 2024-11-21 | N/A |
This vulnerability allows remote attackers to cause a denial-of-service condition on vulnerable installations of ZyXEL P-870H-51 DSL Router 1.00(AWG.3)D5. Authentication is not required to exploit this vulnerability. The specific flaw exists within numerous exposed CGI endpoints. The vulnerability is caused by improper access controls that allow access to critical functions without authentication. An attacker can use this vulnerability to reboot affected devices, along with other actions. Was ZDI-CAN-4540. | ||||
CVE-2018-19636 | 1 Opensuse | 1 Supportutils | 2024-11-21 | N/A |
Supportutils, before version 3.1-5.7.1, when run with command line argument -A searched the file system for a ndspath binary. If an attacker provides one at an arbitrary location it is executed with root privileges | ||||
CVE-2018-19248 | 1 Epson | 2 Epson Workforce Wf-2861, Epson Workforce Wf-2861 Firmware | 2024-11-21 | N/A |
The web service on Epson WorkForce WF-2861 10.48 LQ22I3(Recovery-mode), WF-2861 10.51.LQ20I6, and WF-2861 10.52.LQ17IA devices allows remote attackers to upload a firmware file and reset the printer without authentication by making a request to the /DOWN/FIRMWAREUPDATE/ROM1 URI and a POST request to the /FIRMWAREUPDATE URI. | ||||
CVE-2018-19079 | 2 Foscam, Opticam | 6 C2, C2 Application Firmware, C2 System Firmware and 3 more | 2024-11-21 | N/A |
An issue was discovered on Foscam Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The ONVIF devicemgmt SystemReboot method allows unauthenticated reboot. | ||||
CVE-2018-18995 | 1 Abb | 4 Gate-e1, Gate-e1 Firmware, Gate-e2 and 1 more | 2024-11-21 | N/A |
Pluto Safety PLC Gateway Ethernet devices ABB GATE-E1 and GATE-E2 all versions do not allow authentication to be configured on administrative telnet or web interfaces, which could enable various effects vectors, including conducting device resets, reading or modifying registers, and changing configuration settings such as IP addresses. | ||||
CVE-2018-18264 | 1 Kubernetes | 1 Dashboard | 2024-11-21 | N/A |
Kubernetes Dashboard before 1.10.1 allows attackers to bypass authentication and use Dashboard's Service Account for reading secrets within the cluster. | ||||
CVE-2018-17924 | 1 Rockwellautomation | 32 1756-en2f Series A, 1756-en2f Series A Firmware, 1756-en2f Series B and 29 more | 2024-11-21 | 8.6 High |
Rockwell Automation MicroLogix 1400 Controllers and 1756 ControlLogix Communications Modules An unauthenticated, remote threat actor could send a CIP connection request to an affected device, and upon successful connection, send a new IP configuration to the affected device even if the controller in the system is set to Hard RUN mode. When the affected device accepts this new IP configuration, a loss of communication occurs between the device and the rest of the system as the system traffic is still attempting to communicate with the device via the overwritten IP address. | ||||
CVE-2018-17906 | 1 Philips | 2 Intellispace Pacs, Isite Pacs | 2024-11-21 | 8.8 High |
Philips iSite and IntelliSpace PACS, iSite PACS, all versions, and IntelliSpace PACS, all versions. Default credentials and no authentication within third party software may allow an attacker to compromise a component of the system. | ||||
CVE-2018-17880 | 2 D-link, Dlink | 2 Dir-823g Firmware, Dir-823g | 2024-11-21 | N/A |
On D-Link DIR-823G 2018-09-19 devices, the GoAhead configuration allows /HNAP1 RunReboot commands without authentication to trigger a reboot. |