CVE-2024-6964 | 1 Tenda | 2 O3, O3 Firmware1.0.0.10\(2478\) | 2024-11-21 | 8.8 High |
A vulnerability, which was classified as critical, was found in Tenda O3 1.0.0.10. Affected is the function fromDhcpSetSer. The manipulation of the argument dhcpEn/startIP/endIP/preDNS/altDNS/mask/gateway leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-272118 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-6963 | 1 Tenda | 3 O3, O3 Firmware1.0.0.10\(2478\), O3v2 Firmware | 2024-11-21 | 8.8 High |
A vulnerability, which was classified as critical, has been found in Tenda O3 1.0.0.10. This issue affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-272117 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-6962 | 1 Tenda | 3 O3, O3 Firmware1.0.0.10\(2478\), O3v2 | 2024-11-21 | 8.8 High |
A vulnerability classified as critical was found in Tenda O3 1.0.0.10. This vulnerability affects the function formQosSet. The manipulation of the argument remark/ipRange/upSpeed/downSpeed/enable leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-272116. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-41473 | 2 Tenda, Tendacn | 3 Fh1201 Firmware, Fh1201, Fh1201 Firmware | 2024-11-21 | 8 High |
Tenda FH1201 v1.2.0.14 was discovered to contain a command injection vulnerability via the mac parameter at ip/goform/WriteFacMac | ||||
CVE-2024-41468 | 2 Tenda, Tendacn | 3 Fh1201, Fh1201, Fh1201 Firmware | 2024-11-21 | 9.8 Critical |
Tenda FH1201 v1.2.0.14 was discovered to contain a command injection vulnerability via the cmdinput parameter at /goform/exeCommand | ||||
CVE-2024-41466 | 2 Tenda, Tendacn | 3 Fh1201 Firmware, Fh1201, Fh1201 Firmware | 2024-11-21 | 7.5 High |
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the page parameter at ip/goform/NatStaticSetting. | ||||
CVE-2024-41465 | 2 Tenda, Tendacn | 3 Fh1201 Firmware, Fh1201, Fh1201 Firmware | 2024-11-21 | 7.5 High |
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter at ip/goform/setcfm. | ||||
CVE-2024-41464 | 2 Tenda, Tendacn | 3 Fh1201, Fh1201, Fh1201 Firmware | 2024-11-21 | 9.8 Critical |
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the mitInterface parameter in ip/goform/RouteStatic | ||||
CVE-2024-41463 | 2 Tenda, Tendacn | 3 Fh1201 Firmware, Fh1201, Fh1201 Firmware | 2024-11-21 | 4.3 Medium |
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the entrys parameter at ip/goform/addressNat. | ||||
CVE-2024-41462 | 2 Tenda, Tendacn | 3 Fh1201 Firmware, Fh1201, Fh1201 Firmware | 2024-11-21 | 4.3 Medium |
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the page parameter at ip/goform/DhcpListClient. | ||||
CVE-2024-41461 | 2 Tenda, Tendacn | 3 Fh1201, Fh1201, Fh1201 Firmware | 2024-11-21 | 9.8 Critical |
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the list1 parameter at ip/goform/DhcpListClient. | ||||
CVE-2024-41460 | 2 Tenda, Tendacn | 3 Fh1201 Firmware, Fh1201, Fh1201 Firmware | 2024-11-21 | 6.5 Medium |
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the entrys parameter at ip/goform/RouteStatic. | ||||
CVE-2024-41459 | 2 Tenda, Tendacn | 3 Fh1201 Firmware, Fh1201, Fh1201 Firmware | 2024-11-21 | 8.8 High |
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the PPPOEPassword parameter at ip/goform/QuickIndex. | ||||
CVE-2024-40416 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2024-11-21 | 6.5 Medium |
A vulnerability in /goform/SetVirtualServerCfg in the sub_6320C function in Tenda AX1806 1.0.0.1 firmware leads to stack-based buffer overflow. | ||||
CVE-2024-40415 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2024-11-21 | 9.8 Critical |
A vulnerability in /goform/SetStaticRouteCfg in the sub_519F4 function in Tenda AX1806 1.0.0.1 firmware leads to stack-based buffer overflow. | ||||
CVE-2024-40414 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2024-11-21 | 9.6 Critical |
A vulnerability in /goform/SetNetControlList in the sub_656BC function in Tenda AX1806 1.0.0.1 firmware leads to stack-based buffer overflow. | ||||
CVE-2024-33180 | 2 Tenda, Tendacn | 3 Ac18, Ac18, Ac18 Firmware | 2024-11-21 | 9.8 Critical |
Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/saveParentControlInfo. | ||||
CVE-2024-30621 | 1 Tenda | 2 Ax1803, Ax1803 Firmware | 2024-11-21 | 9.8 Critical |
Tenda AX1803 v1.0.0.1 contains a stack overflow via the serverName parameter in the function fromAdvSetMacMtuWan. | ||||
CVE-2024-2856 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-21 | 8.8 High |
A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257780. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2855 | 1 Tenda | 2 Ac15, Ac15 Firmware | 2024-11-21 | 8.8 High |
A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.05.19/15.03.20. Affected by this vulnerability is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257779. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |