| CVE-2011-4515 | 1 Siemens | 1 Wincc Tia Portal | 2025-04-11 | N/A |
| Siemens WinCC (TIA Portal) 11 uses a reversible algorithm for storing HMI web-application passwords in world-readable and world-writable files, which allows local users to obtain sensitive information by leveraging (1) physical access or (2) Sm@rt Server access. | ||||
| CVE-2013-3633 | 1 Siemens | 7 Scalance X200-4p Irt, Scalance X200irt Firmware, Scalance X201-3p Irt and 4 more | 2025-04-11 | N/A |
| A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions < V5.0.0 for CVE-2013-3633 and versions < V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.1.0). The user privileges for the web interface are only enforced on client side and not properly verified on server side. Therefore, an attacker is able to execute privileged commands using an unprivileged account. | ||||
| CVE-2012-2596 | 1 Siemens | 1 Wincc | 2025-04-11 | N/A |
| The XPath functionality in unspecified web applications in Siemens WinCC 7.0 SP3 before Update 2 does not properly handle special characters in parameters, which allows remote authenticated users to read or modify settings via a crafted URL, related to an "XML injection" attack. | ||||
| CVE-2011-4514 | 1 Siemens | 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more | 2025-04-11 | N/A |
| The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attackers to obtain access via a TCP session. | ||||
| CVE-2013-5709 | 1 Siemens | 9 Scalance X-200, Scalance X-200 Series Firmware, Scalance X-200rna and 6 more | 2025-04-11 | N/A |
| The authentication implementation in the web server on Siemens SCALANCE X-200 switches with firmware before 5.0.0 does not use a sufficient source of entropy for generating values of random numbers, which makes it easier for remote attackers to hijack sessions by predicting a value. | ||||
| CVE-2011-3321 | 1 Siemens | 2 Simatic Wincc Flexible Runtime, Simatic Wincc Runtime | 2025-04-11 | N/A |
| Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308. | ||||
| CVE-2011-4877 | 1 Siemens | 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more | 2025-04-11 | N/A |
| HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cause a denial of service (application crash) by sending crafted data over TCP. | ||||
| CVE-2011-4529 | 1 Siemens | 1 Automation License Manager | 2025-04-11 | N/A |
| Multiple buffer overflows in Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 allow remote attackers to execute arbitrary code via a long serialid field in an _licensekey command, as demonstrated by the (1) check_licensekey or (2) read_licensekey command. | ||||
| CVE-2013-4912 | 1 Siemens | 1 Wincc | 2025-04-11 | N/A |
| Open redirect vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP1 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks by leveraging improper configuration of SIMATIC HMI panels by the WinCC product. | ||||
| CVE-2013-5944 | 1 Siemens | 3 Scalance X-200, Scalance X-200 Series Firmware, Scalance X-200irt | 2025-04-11 | N/A |
| The integrated web server on Siemens SCALANCE X-200 switches with firmware before 4.5.0 and X-200IRT switches with firmware before 5.1.0 does not properly enforce authentication requirements, which allows remote attackers to perform administrative actions via requests to the management interface. | ||||
| CVE-2013-4651 | 1 Siemens | 17 Scalance W700 Series Firmware, Scalance W744-1, Scalance W744-1pro and 14 more | 2025-04-11 | N/A |
| Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers' installations, which makes it easier for remote attackers to conduct man-in-the-middle attacks against SSL sessions by leveraging the certificate's trust relationship. | ||||
| CVE-2013-4652 | 1 Siemens | 17 Scalance W700 Series Firmware, Scalance W744-1, Scalance W744-1pro and 14 more | 2025-04-11 | N/A |
| Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices with firmware before 4.5.4 allows remote attackers to bypass authentication and execute arbitrary code via a (1) SSH or (2) TELNET connection. | ||||
| CVE-2013-3958 | 1 Siemens | 2 Simatic Pcs7, Wincc | 2025-04-11 | N/A |
| The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request. | ||||
| CVE-2013-3959 | 1 Siemens | 2 Simatic Pcs7, Wincc | 2025-04-11 | N/A |
| The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters. | ||||
| CVE-2013-3634 | 1 Siemens | 7 Scalance X200-4p Irt, Scalance X200irt Firmware, Scalance X201-3p Irt and 4 more | 2025-04-11 | N/A |
| A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions < V5.0.0 for CVE-2013-3633 and versions < V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.1.0). The implementation of SNMPv3 does not check the user credentials sufficiently. Therefore, an attacker is able to execute SNMP commands without correct credentials. | ||||
| CVE-2011-4056 | 1 Siemens | 1 Tecnomatix Factorylink | 2025-04-11 | N/A |
| An unspecified ActiveX control in ActBar.ocx in Siemens Tecnomatix FactoryLink 6.6.1 (aka 6.6 SP1), 7.5.217 (aka 7.5 SP2), and 8.0.2.54 allows remote attackers to create or overwrite arbitrary files via the save method. | ||||
| CVE-2012-3016 | 1 Siemens | 6 Simatic S7-400 Cpu 412-2 Pn, Simatic S7-400 Cpu 414-3 Pn\/dp, Simatic S7-400 Cpu 414f-3 Pn\/dp and 3 more | 2025-04-11 | N/A |
| Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service (defect-mode transition and service outage) via crafted ICMP packets. | ||||
| CVE-2011-3389 | 9 Canonical, Debian, Google and 6 more | 21 Ubuntu Linux, Debian Linux, Chrome and 18 more | 2025-04-11 | N/A |
| The SSL protocol, as used in certain configurations in Microsoft Windows and Microsoft Internet Explorer, Mozilla Firefox, Google Chrome, Opera, and other products, encrypts data by using CBC mode with chained initialization vectors, which allows man-in-the-middle attackers to obtain plaintext HTTP headers via a blockwise chosen-boundary attack (BCBA) on an HTTPS session, in conjunction with JavaScript code that uses (1) the HTML5 WebSocket API, (2) the Java URLConnection API, or (3) the Silverlight WebClient API, aka a "BEAST" attack. | ||||
| CVE-2011-4510 | 1 Siemens | 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more | 2025-04-11 | N/A |
| Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4511. | ||||
| CVE-2011-4509 | 1 Siemens | 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more | 2025-04-11 | N/A |
| The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account, which makes it easier for remote attackers to obtain access via a brute-force approach involving many HTTP requests. | ||||