CVE-2015-5374 1 Siemens 3 Siprotec 4, Siprotec Compact, Siprotec Firmware 2025-04-12 N/A
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device.
CVE-2014-2250 1 Siemens 6 Simatic S7 Cpu-1211c, Simatic S7 Cpu 1200 Firmware, Simatic S7 Cpu 1212c and 3 more 2025-04-12 N/A
The random-number generator on Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms and hijack sessions via unspecified vectors, a different vulnerability than CVE-2014-2251.
CVE-2016-7114 1 Siemens 2 En100 Ethernet Module, En100 Ethernet Module Firmware 2025-04-12 N/A
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.87; SIPROTEC 7UT686 : All versions < V 4.02; SIPROTEC 7SD686 : All versions < V 4.05; SIPROTEC 7SJ66 : All versions < V 4.30. Attackers with network access to the device's web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful.
CVE-2016-7112 1 Siemens 2 En100 Ethernet Module, En100 Ethernet Module Firmware 2025-04-12 N/A
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Attackers with network access to the device's web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations.
CVE-2014-0224 9 Fedoraproject, Filezilla-project, Mariadb and 6 more 23 Fedora, Filezilla Server, Mariadb and 20 more 2025-04-12 7.4 High
OpenSSL before 0.9.8za, 1.0.0 before 1.0.0m, and 1.0.1 before 1.0.1h does not properly restrict processing of ChangeCipherSpec messages, which allows man-in-the-middle attackers to trigger use of a zero-length master key in certain OpenSSL-to-OpenSSL communications, and consequently hijack sessions or obtain sensitive information, via a crafted TLS handshake, aka the "CCS Injection" vulnerability.
CVE-2014-8552 1 Siemens 4 Simatic Pcs7, Simatic Pcs 7, Simatic Tiaportal and 1 more 2025-04-12 N/A
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets.
CVE-2014-0160 13 Broadcom, Canonical, Debian and 10 more 37 Symantec Messaging Gateway, Ubuntu Linux, Debian Linux and 34 more 2025-04-12 7.5 High
The (1) TLS and (2) DTLS implementations in OpenSSL 1.0.1 before 1.0.1g do not properly handle Heartbeat Extension packets, which allows remote attackers to obtain sensitive information from process memory via crafted packets that trigger a buffer over-read, as demonstrated by reading private keys, related to d1_both.c and t1_lib.c, aka the Heartbleed bug.
CVE-2015-1602 1 Siemens 1 Simatic Step 7 2025-04-12 N/A
Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 improperly stores password data within project files, which makes it easier for local users to determine cleartext (1) protection-level passwords or (2) web-server passwords by leveraging the ability to read these files.
CVE-2016-6486 1 Siemens 1 Sinema Server 2025-04-12 N/A
Siemens SINEMA Server uses weak permissions for the application folder, which allows local users to gain privileges via unspecified vectors.
CVE-2015-1597 1 Siemens 1 Spcanywhere 2025-04-12 N/A
The Siemens SPCanywhere application for Android does not use encryption during the loading of code, which allows man-in-the-middle attackers to execute arbitrary code by modifying the client-server data stream.
CVE-2013-0679 1 Siemens 2 Simatic Pcs7, Wincc 2025-04-11 N/A
Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname.
CVE-2013-0677 1 Siemens 2 Simatic Pcs7, Wincc 2025-04-11 N/A
The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to obtain sensitive information or cause a denial of service via a crafted project file.
CVE-2013-0676 1 Siemens 2 Simatic Pcs7, Wincc 2025-04-11 N/A
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly assign privileges for the database containing WebNavigator credentials, which allows remote authenticated users to obtain sensitive information via a SQL query.
CVE-2013-0672 1 Siemens 1 Wincc Tia Portal 2025-04-11 N/A
Cross-site scripting (XSS) vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to inject arbitrary web script or HTML via unspecified data.
CVE-2013-0675 1 Siemens 2 Simatic Pcs7, Wincc 2025-04-11 N/A
Buffer overflow in CCEServer (aka the central communications component) in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to cause a denial of service via a crafted packet.
CVE-2014-1966 1 Siemens 3 Ruggedcom Rs950g, Ruggedcom Rsg2488, Ruggedcom Rugged Operating System 2025-04-11 N/A
The SNMP implementation in Siemens RuggedCom ROS before 3.11, ROS 3.11 for RS950G, ROS 3.12 before 3.12.4, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service (device outage) via crafted packets.
CVE-2013-0671 1 Siemens 1 Wincc Tia Portal 2025-04-11 N/A
Directory traversal vulnerability in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to read HMI web-application source code and user-defined scripts via a crafted URL.
CVE-2013-0670 1 Siemens 1 Wincc Tia Portal 2025-04-11 N/A
CRLF injection vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via a crafted URL.
CVE-2013-0659 1 Siemens 4 Cp 1604, Cp 1604 Firmware, Cp 1616 and 1 more 2025-04-11 N/A
The debugging feature on the Siemens CP 1604 and CP 1616 interface cards with firmware before 2.5.2 allows remote attackers to execute arbitrary code via a crafted packet to UDP port 17185.
CVE-2013-0669 1 Siemens 1 Wincc Tia Portal 2025-04-11 N/A
The HMI web application in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to cause a denial of service (daemon crash) via a crafted HTTP request.