| CVE-2017-14473 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | N/A |
| An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: Any Description: Reads the encoded ladder logic from its data file and print it out in HEX. | ||||
| CVE-2017-14472 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | N/A |
| An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: Any Description: Requests a specific set of bytes from an undocumented data file and returns the ASCII version of the master password. | ||||
| CVE-2017-14471 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | N/A |
| An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Associated Fault Codes: 0023, 002e, and 0037 Fault Type: Recoverable Description: The STI, EII, and HSC function files contain bits signifying whether or not a fault has occurred. Additionally there is a bit signaling the module to auto start. When these bits are set for any of the three modules and the device is moved into a run state, a fault is triggered. | ||||
| CVE-2017-14470 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | N/A |
| An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG or RUN Description: The value 0xffffffff is considered NaN for the Float data type. When a float is set to this value and used in the PLC, a fault is triggered. NOTE: This is not possible through RSLogix. | ||||
| CVE-2017-14469 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | N/A |
| An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Associated Fault Code: 0028 Fault Type: Non-User Description: Values 0x01 and 0x02 are invalid values for the user fault routine. By writing directly to the file it is possible to set these values. When this is done and the device is moved into a run state, a fault is triggered. NOTE: This is not possible through RSLogix. | ||||
| CVE-2017-14468 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | 9.8 Critical |
| An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Description: This ability is leveraged in a larger exploit to flash custom firmware. | ||||
| CVE-2017-14467 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | 9.8 Critical |
| An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE Description: Live rung edits are able to be made by an unauthenticated user allowing for addition, deletion, or modification of existing ladder logic. Additionally, faults and cpu state modification can be triggered if specific ladder logic is used. | ||||
| CVE-2017-14466 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | 9.8 Critical |
| An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Description: The filetype 0x03 allows users write access, allowing the ability to overwrite the Master Password value stored in the file. | ||||
| CVE-2017-14465 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | 9.8 Critical |
| An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE Description: Any input or output can be forced, causing unpredictable activity from the PLC. | ||||
| CVE-2017-14464 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | 9.8 Critical |
| An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability.Required Keyswitch State: REMOTE or PROG Associated Fault Code: 0001 Fault Type: Non-User Description: A fault state can be triggered by setting the NVRAM/memory module user program mismatch bit (S2:9) when a memory module is NOT installed. | ||||
| CVE-2017-14463 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | 9.8 Critical |
| An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Associated Fault Code: 0012 Fault Type: Non-User Description: A fault state can be triggered by overwriting the ladder logic data file (type 0x22 number 0x02) with null values. | ||||
| CVE-2017-14462 | 1 Rockwellautomation | 2 Micrologix 1400, Micrologix 1400 B Firmware | 2024-11-21 | 9.8 Critical |
| An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG (also RUN for some) Description: Allows an attacker to enable SNMP, Modbus, DNP, and any other features in the channel configuration. Also allows attackers to change network parameters, such as IP address, name server, and domain name. | ||||
| CVE-2017-14461 | 3 Debian, Dovecot, Ubuntu | 3 Debian Linux, Dovecot, Ubuntu | 2024-11-21 | N/A |
| A specially crafted email delivered over SMTP and passed on to Dovecot by MTA can trigger an out of bounds read resulting in potential sensitive information disclosure and denial of service. In order to trigger this vulnerability, an attacker needs to send a specially crafted email message to the server. | ||||
| CVE-2017-14460 | 1 Parity | 1 Ethereum Client | 2024-11-21 | N/A |
| An exploitable overly permissive cross-domain (CORS) whitelist vulnerability exists in JSON-RPC of Parity Ethereum client version 1.7.8. An automatically sent JSON object to JSON-RPC endpoint can trigger this vulnerability. A victim needs to visit a malicious website to trigger this vulnerability. | ||||
| CVE-2017-14459 | 1 Moxa | 2 Awk-3131a, Awk-3131a Firmware | 2024-11-21 | N/A |
| An exploitable OS Command Injection vulnerability exists in the Telnet, SSH, and console login functionality of Moxa AWK-3131A Industrial IEEE 802.11a/b/g/n wireless AP/bridge/client in firmware versions 1.4 to 1.7 (current). An attacker can inject commands via the username parameter of several services (SSH, Telnet, console), resulting in remote, unauthenticated, root-level operating system command execution. | ||||
| CVE-2017-14458 | 1 Foxit | 1 Pdf Reader | 2024-11-21 | 8.8 High |
| An exploitable use-after-free vulnerability exists in the JavaScript engine of Foxit Software's Foxit PDF Reader version 8.3.2.25013. A specially crafted PDF document can trigger a previously freed object in memory to be reused, resulting in arbitrary code execution. An attacker needs to trick the user to open the malicious file to trigger this vulnerability. If the browser plugin extension is enabled, visiting a malicious site can also trigger the vulnerability. | ||||
| CVE-2017-14457 | 1 Ethereum | 1 Ethereum Virtual Machine | 2024-11-21 | 8.2 High |
| An exploitable information leak/denial of service vulnerability exists in the libevm (Ethereum Virtual Machine) `create2` opcode handler of CPP-Ethereum. A specially crafted smart contract code can cause an out-of-bounds read leading to memory disclosure or denial of service. An attacker can create/send malicious a smart contract to trigger this vulnerability. | ||||
| CVE-2017-14455 | 1 Insteon | 2 Hub 2245-222, Hub 2245-222 Firmware | 2024-11-21 | N/A |
| On Insteon Hub 2245-222 devices with firmware version 1012, specially crafted replies received from the PubNub service can cause buffer overflows on a global section overwriting arbitrary data. An attacker should impersonate PubNub and answer an HTTPS GET request to trigger this vulnerability. A strcpy overflows the buffer insteon_pubnub.channel_ak, which has a size of 16 bytes. An attacker can send an arbitrarily long "ak" parameter in order to exploit this vulnerability. | ||||
| CVE-2017-14453 | 1 Insteon | 2 Hub 2245-222, Hub 2245-222 Firmware | 2024-11-21 | N/A |
| On Insteon Hub 2245-222 devices with firmware version 1012, specially crafted replies received from the PubNub service can cause buffer overflows on a global section overwriting arbitrary data. An attacker should impersonate PubNub and answer an HTTPS GET request to trigger this vulnerability. A strcpy overflows the buffer insteon_pubnub.channel_ad_r, which has a size of 16 bytes. An attacker can send an arbitrarily long "ad_r" parameter in order to exploit this vulnerability. | ||||
| CVE-2017-14452 | 1 Insteon | 2 Hub, Hub Firmware | 2024-11-21 | N/A |
| An exploitable buffer overflow vulnerability exists in the PubNub message handler for the "control" channel of Insteon Hub running firmware version 1012. Specially crafted replies received from the PubNub service can cause buffer overflows on a global section overwriting arbitrary data. A strcpy overflows the buffer insteon_pubnub.channel_cc_r, which has a size of 16 bytes. An attacker can send an arbitrarily long "c_r" parameter in order to exploit this vulnerability. An attacker should impersonate PubNub and answer an HTTPS GET request to trigger this vulnerability. | ||||